Compaq External RAID Controller & Subsystem Bedienungsanleitung Seite 158

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 347
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 157
Infortrend
7-39
Press Yes to confirm.
A prompt will notify you that the controller NVRAM data has been
successfully restored from disks.
Password Validation Timeout
Choose “View and Edit Configuration parameters,” “Controller
Parameters,” then press [ENTER]. Select “Password Validation
Timeout,” and press [ENTER]. Choose to enable a validation
timeout from one minute to always check. The always check
timeout will disable any configuration change made without
entering the correct password.
Controller Unique Identifier
Enter any hex number between “0” and “FFFFF” for the unique
identifier. The value you enter MUST be different for each
controller.
The Controller Unique Identifier is
required
for configuring every
RAID controller
.
The controller automatically notifies users to enter
a unique identifier when the first logical drive is created in a dual-
controller system.
Seitenansicht 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 346 347

Kommentare zu diesen Handbüchern

Keine Kommentare