Seitenansicht 114
Infortrend
6-6
6.6 SCSI Drive Status
Slot
Slot number of the drive;
“S” indicates this is the drive used for passing through SES
signals
Chl
The drive channel where the drive is connected
X<Y> indicates two channels are configured in a dual-loop
ID
The channel ID assigned to this drive
Size (MB)
Drive capacity
Speed
XxMB Maximum transfer rate of drive channel interface
Async The drive is using asynchronous mode.
LG_DRV X
The drive is a drive member of logical drive x.
If the Status column shows “STAND-BY”, the drive
is a Local Spare of logical drive x.
Status Global
The SCSI drive is a Global Spare Drive
INITING
Processing array initialization
ON-LINE
The drive is in good condition
REBUILD
Processing Rebuild
STAND-BY
Local Spare Drive or Global Spare Drive. The
Local Spare Drive’s LG_DRV column will show
the logical drive number. The Global Spare
Drive’s LG_DRV column will show “Global”.
NEW DRV
A new drive has not been configured to any
logical drive or as a spare drive
USED DRV
An used drive that is not a member of any
logical drive or configured as spare
BAD
Failed drive
ABSENT
Drive does not exist
MISSING
Drive once existed, but is missing now
SB-MISS
Spare drive missing
Vendor and
Product ID
The vendor and product model information of
the drive
Seitenansicht 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 346 347

Kommentare zu diesen Handbüchern

Keine Kommentare