Terminal Screen Messages
6-5
Column C Logical Drive Status – Write Policy setting
B
Write-back
T
Write-through
#LN
Total drive members in the logical drive
#SB
Standby drives available for the logical drive. This
includes all the spare drives (local spare, global spare)
available for the specific logical drive
#FL
Number of Failed member(s) in the logical drive
Name
Logical drive name (user configurable)
6.5 Logical Volume Status
LV
Logical Volume number.
P0: Logical Volume 0 managed by the Primary Controller
S0: Logical Volume 0 managed by the Secondary Controller
ID
Logical Volume ID number (controller randomly generated)
Size(MB)
Capacity of the Logical Volume
#LD
The number of Logical Drive(s) included in this Logical Volume