7–75
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
SECONDS=nn
As soon as the POWEROFF command is entered, all disk units in the cabinet are set
to write-through. When the time interval, as represented by nn seconds, has elapsed,
an orderly rundown of all units is started. When all units in the cabinet are
successfully rundown, the cabinet power is turned off.
Table 7–3 shows what action will be taken depending on the switch settings and the
results of the attempted flush:
Table 7–3. POWEROFF Switch Settings
Battery Switch Override Switch Flush
Results
Action
BATTERY_ON OVERRIDE_BAD_FLUSH Success Controller and units in cabinet
shutdown, ECB charger remains on.
BATTERY_ON OVERRIDE_BAD_FLUSH Failure Controller and units in cabinet
shutdown, ECB charger remains on.
BATTERY_ON NO_OVERRIDE_BAD_FLUSH Success Controller and units in cabinet
shutdown, ECB charger remains on.
BATTERY_ON NO_OVERRIDE_BAD_FLUSH Failure Nothing is shutdown, ECB charger
remains on, user is notified of a bad
flush.
BATTERY_OFF OVERRIDE_BAD_FLUSH Success Controller and units in cabinet
shutdown, ECB charger turned off.
BATTERY_OFF OVERRIDE_BAD_FLUSH Failure Controller and units in cabinet
shutdown, ECB charger turned off.
BATTERY_OFF NO_OVERRIDE_BAD_FLUSH Success Controller and units in cabinet
shutdown, ECB charger turned off.
BATTERY_OFF NO_OVERRIDE_BAD_FLUSH Failure Nothing is shutdown, ECB charger
remains on, user is notified of a bad
flush.