4–38
Planning Storagesets
RECONSTRUCT=NORMAL (default) balances the overall performance of the
subsystem against the need for reconstructing the replacement disk drive.
RECONSTRUCT=FAST gives more resources to reconstructing the replacement
disk drive, which may reduce the subsystems overall performance during the
reconstruction task.
Membership
Indicate to the controller that the RAIDset you are adding is either complete or
reduced, which means it is missing one of its members:
NOREDUCED (default) indicates to the controller that all of the disk drives are
present for a RAIDset.
REDUCED lets you add a RAIDset that is missing one of its members. For
example, if you dropped or destroyed a disk drive while moving a RAIDset, you
could still add it to the subsystem by using this switch.