Seitenansicht 207
7–12
CLI Commands
Examples
To add DISK10000 at port 1, target 0, LUN 0, type:
ADD DISK DISK10000 1 0 0
To add DISK40200 as a transportable disk drive to port 4, target 2, LUN 0, use:
ADD DISK DISK40200 4 2 0 TRANSPORTABLE
To add a disk drive named DISK30200 as non-transportable disk to port 3, target 2,
LUN 0, and to set the data transfer rate to 10 MHz, enter the following command on
one line.
ADD DISK DISK30200 3 2 0 NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED=10MHZ
This example creates a host-addressable unit after the disk is added:
INITIALIZE DISK20000
ADD UNIT D199 DISK20000
See also
ADD MIRRORSET
ADD UNIT
DELETE container-name
LOCATE
SHOW DISKS
SHOW DEVICES
SET container-name