2.4.7 Adjusting the Purity
(1) Input the check 4 timing (85Hz, 1600 x 1200) to confirm that the GREEN crosshatch is
displayed in reverse.
(2) Set the chamber adjustment magnetic field to the northern hemisphere magnetic field
(HORIZ. = 0mT, VERT. = +0.04mT).
(Degauss by handy-demagnetizer with monitor set degauss operation.)
(3) Set the monitor to the factory mode from the front, select CP P OFF, and press Input
Connector Select / OSD OFF button once.
With this, the calibration of the horizontal (tube axis) one way geomagnetism sensor will be
carried out by the MPU. ("H/V MAG CAL" is displayed.)
Adjustment item
Purity
Adjustment mode/set
Factory
Imput signal/pattern
Check 4 : 85Hz, 1600x1200
GREEN crosshatch reverse
Status
indicator
2.4.6.3 Adjustment of X-Pro (Timing No. A 30k/70Hz Full white)
(1) Select XPRO-CALIBRATE by button and press (+) button.
(When (+) button is pressed, microcomputer automatically sets the protector.)
(2) Confirm that OK is indicated on OSD.
2.4.6.4 Confirmation for operation of X-Pro (Timing No. 25 1800 x 1350 at 85Hz, Full white)
(1) Select XPRO-TEST 28 mode by button and press (+) button.
(2) Confirm that OK is indicated on OSD without entering power save state.
(3) Change to full white of timing No. A, select XPRO-TEST 31 mode by
button, and press
(+) button.
(4) Confirm that X-Pro operates and enters into the self-diagnosis mode (LED flacker: color
amber for a second, OFF a second, color amber for 4 seconds, OFF 1 second, and re-
frain).