Compaq P1220 Wartungshandbuch Seite 90

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 210
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 89
2 - 9
DBF-H-AMP / PHASE adjustment
DBF-V-AMP adjustment
(6) If the left and right distortions differ, select PIN-BALANCE, KEY-BALANCE, TOP-BAL-
ANCE and BOTTOM-BALANCE with the OSD, and adjust so that the distortions are visu-
ally balanced.
(7) Select H-PHASE with the OSD, and adjust the horizontal raster position to the center of
the picture using the ADJUST buttons.
(8) Select H-SIZE with the OSD, and adjust the horizontal raster width to the value given in
the adjustment list using the ADJUST buttons. (Refer to 2.5.1.10 Adjustment value list.)
* Note (1) PCC-SINE and PIN-BALANCE are used only for touch up.
* Note (2) The picture position and distortion must be within the ranges given in the
picture performance inspection items. (Refer to 2.5.1.8 Picture distortion.)
2.4.4.4 Adjusting the DBF amplitude and phase
(1) Connect the oscilloscope to the lead of R7A2 (AG703 side) on PWB-MAIN and to one of
the signal outputs for the signal sources full R, G, B (VIDEO).
(2) Set the OSD to the select picture of DBF-H-AMP, and using the (-) (+) ADJUST buttons
adjust the horizontal parabola wave amplitude (Video area) to the value given in the list of
adjustment values. (Refer to 2.5.1.10 Adjustment value list.)
(3) Set the OSD to the select picture of DBF-H-PHASE, and using the (-) (+) ADJUST buttons
adjust the horizontal parabola wave phase as shown below in respect to the image signal.
(4) Set the OSD to the DBF-V-AMP select picture, and using the (-) (+) ADJUST buttons adjust
the vertical parabola wave amplitude (video area) to the value given in the list of adjust-
ment values. (Refer to 2.5.1.10 Adjustment value list.)
Video signal 1V
Vertical parabola wave
DBF-V-AMP
Measure
the cente
r.
DBF-H-PHASE
DBF-H-AMP
Video signal
Horizontal parabola wave
The center of the horizontal
parabola waveform and
center of the image signal
waveform must match.