13 FCOs
Table 13: FCO summary for DEC/VAX/7000/10000
FCO SB# Description
7xxx-F001 747 Removing C49 from blower servo stops it self-destructing
Quick Check: blowers with serial nos. above 675 or marked with green dots are
OK
Kit: EQ-01656-01
7xxx-F002 751 New door catches + air pressure switch on CCL bypassed
Quick check: door catches at rev D01 and CCL at rev J03 or greater are OK
Kit: EQ-01666-01
7xxx-F003 758 Various power parts and cables upgraded to ensure FCC Compliance. Spares
only affected
Quick check: see FCO document
Kit: EQ-01675-xx
7xxx-F004 763 New VAX CPU modules remove memory interleaving restriction and fix Cache
ECC problems
Quick check: CPU modules (E2045-AA) at rev P07 or higher are OK
Kit: EQ-01673-01
7xxx-F005 New CCL module fixes potential power up problem due to C14 reversed. Only
7xx0s from Ayr between weeks 21 and 31 (1994) are affected
Quick check: See FCO document or Section 14.3, Other Goodies
Kit: EQ-01708-01
10xxx-F001 763 Same as 7xxx-F004, but for 10xxx systems
KFMSB-O001 773 New adapter supports LFU and does 2 byte write properly
Quick check: KFMSB-AA (T2029-AC) is rev C02 or higher
Kit: EQ-01709-01
KN7AA-O001 773 New DEC CPU fixes memory interleave and cache ECC problems
Quick check: CPU is E2040-YA at Rev E01 or higher
Kit: EQ-01694-01
KN7AA-F002 765 Rev E* LAMB module (T2028-AA) allows byte addressing for BI and VME options
on DEC 7000/10000. Spares only affected
Quick check: T2028-AA = rev E*
Kit: EQ-01686-01, not available in Europe
KZMSA-F001 757 New KZMSA for DEC 7000 systems allows onsite ucode update (via LFU)
Quick check: KZMSA modules (T2029-AB) at rev F are OK
Kit: EQ-01674-01
The FCO originally said rev P06 modules were OK, but some turned out to have bad TAG
RAMs. See FCO document for full details, but basically, modules below rev P06 need
replacing, those at P06 may need replacing and those above P06 do not need replacing.
Beware, this FCO appeared on SB 776, called 7xxx-F004 and 10xxx-F001. These are
the numbers for the VAX CPU FCO!!