2.5. Module Power Requirements
2.6. LED Indicators
The MPAC and MPDC power supply module have two LED indicators: PWR and ALM.
a) The PWR (Power) LED veries, by lighting solid green, that the power supply is supplying 24 VDC powering to the
active MAXNET II chassis.
b) The ALM (Alarm) LED will ash red if there is a problem with the power supply or if any of its monitored functions
are beyond the specied limits.
__________________________________________________
1
If the ALM LED is ashing red at a slow rate of approximately 1s on-1s off, this is indicative of a communications failure between this module and
the chassis. See Troubleshooting section.
MAXNET
®
II – MPAC/MPDC Modular Power Supply – Installation & Operation Manual 2-3
CHAPTER 2: INSTALLATIONCHAPTER 2: INSTALLATION
Module
Max Current (A) 8 0.29 0.52 0.46 0.29 0.52 0.03 0.14 0.47 0.52
MPAC / MPDC
MPRX-8 /
MPRX-16
MPRX2-8
MPRXRR-16 /
MPRXRR-8
MPRX-DC /
MPRX2-DC
MPRX2-DC
MPRFA/B
QMP200
QMP1000
(< 22 dB Gain)
QMP1000
(> 22 dB Gain)
STATUS
FLASHING
RED
1
SOLID
GREEN
OFF
LED
PWR N/A 24V Power ON
Check Power
Supply Module
ALM Module problem N/A
Normal (PWR is
GREEN)
Table #4: LED Status Indications