Service Guide
EK-HSG80-UP. B01 Page 7
5.0 Preparing the Client
NOTE
If you are using a Tru64 system, skip this section (5.0) and
proceed to Section 6.0.
If the StorageWorks Command Console (SWCC) was used to manage this HSZ70 subsystem,
perform the following steps to save a copy of the HSZ70 configuration. If SWCC was not used,
skip this section and go to Section 6.0 Removing the Server Components. The HSZ70 subsystem
configuration can be saved using SWCC. Use the following steps to save the configuration and
prepare the PC where the StorageWorks Command Console (SWCC) is installed:
1. Using the Start Program menu, start the StorageWorks Command Console.
2. Open the folder which corresponds to the system to be upgraded from the StorageWorks
Command Console’s main display.
3. Once the system’s folder is open, double click the Storage Window to open it.
4. Under the Storage menu item select Controller Configuration.
5. Select Save from the Controller Configuration menu.
6. Enter a file name to contain the saved configuration. Be sure to save it in a directory other
than the one in which SWCC is installed, since that directory could be deleted in a
subsequent step in this procedure.
7. Once the file has been saved, close the Storage Window and if it was open, close the
Command Console Window.
8. Uninstall SWCC using the Windows Control Panel icon Add/Remove Programs. Be sure to
remove all of the components including:
• Command Console
• StorageWorks HSZ Storage Window
• StorageWorks CLI Window
9. Once the software has been uninstalled, reboot the PC.