COMPAQ StorageWorks Upgrading From an HSZ70 to an HSG80 Array Controller
Page 6 EK-HSG80-UP. B01
4.0 Preparing the Server
Before starting the upgrade procedure prepare your server using the following steps:
1. Perform a FULL backup and verification of the data on the HSZ70 filesystems or partitions.
Important: Failure to do so could result in the loss of ALL data in the event the upgrade is
not successful.
2. Server Settings: Save a copy of the listed file or document (write down on paper) the settings
of the HSZ70 as seen and configured by the server system. Specifically, make note of
changes to any of the following:
• Host Adapter Settings
• IRIX /var/sysgen/master.d/scip file
• HP-UX /etc/fstab
• ~steam/etc/client.ini file.
NOTE: Save the file if it includes a large number of clients.
• For IBM AIX, list the physical volume IDs; use the lspv command and record the PVIDs
in the table in Appendix A.
Correlate and record the HSZ70 unit numbers versus the host device names in Table A-1 found
in Appendix A. This table will also be used later to record the HSG80 information to create an
HSZ70 to HSG80 unit map. (Some of the information will be filled in later, e.g. HSG80 Host
Device Name). Table 4-1 below is a sample:
Table 4–1 HSZ70 Unit Numbers vs. Host Device Names
HSZ70
Unit
Number
(Operating
System)
Storageset
or JBOD
Name
HSZ70
Host
Device
Special
File
Name
Host
Partition #
or Slice #
Server Mount
Point or Disk
Administrator
Drive Letter
HSG80
Unit
Number
HSG80
Host
Device
Special
File
Name
PVID
D105
(IRIX)
DVGRPR0 dks4d1l5s
7
7 /Genome N/A
D1500
(WIN-NT)
DISK50300 diskNN E: N/A
D800
(SUN)
DISK60000 c2t8d0s0 0 /apps N/A
D900
(HP-UX)
DVGRPS0 c5t1d1 /mnt1 N/A
D600
(Tru64 UX)
DVGRPS1 rx8c /net N/A
D400
IBM AIX
DVGRPS2 hdisk7 /mnt 00201622c6c680a3