Removal and Replacement Procedures 2-51
Hot-Pluggable Power Supply and Midplane Assembly
Compaq ProLiant 8500 servers support up to two hot-pluggable, redundant power supplies.
Hot-Pluggable Power Supply
The system power in the Compaq ProLiant 8500 server does not have to be shut off to replace
one of the power supplies.
To replace a hot-pluggable power supply with the system power on:
1. Remove the power cord from the power supply.
2. Squeeze upward on the release tab in the middle of the power supply handle .
3. Pull the power supply handle down and slide the power supply out of the chassis .
IMPORTANT: Use only power supply part number 122235-001 for the Compaq ProLiant 8500 server.
Power supplies from other servers will not fit.
NOTE: When you remove the power supply, a spring-loaded trap door closes to block the opening. This
door preserves the air path required to cool the internal components of the server.
1
2
3
Figure 2-44. Removing a hot-pluggable power supply
Reverse steps 1 through 3 to replace the hot-pluggable power supply.