Diagnostic Tools 3-49
Table 3-21
ADU Diagnostic Messages
continued
Message Description Recommended Action
Identify logical drive
data did not match
with NVRAM.
The identify unit data from the array
controller did not match with the
information stored in nonvolatile RAM.
This could occur if new, previously
configured drives have been placed in
a system that has also been previously
configured.
Run the System Configuration Utility to
configure the controller and nonvolatile
RAM.
Insufficient adapter
resources
The adapter does not have sufficient
resources to perform operations to the
array accelerator board. Drive rebuild
may be occurring.
Operate the system without the array
accelerator board until the drive rebuild
completes.
Less than 75%
batteries at sufficient
voltage
Operation of array accelerator board
has been disabled due to less than
75% of battery packs being at
sufficient voltage level.
Allow sufficient time for batteries to
recharge (36 hours). If batteries have not
recharged after 36 hours, replace the
array accelerator board.
Less than 75%
batteries at sufficient
voltage. Battery
pack X below
reference voltage.
Battery pack on array accelerator is
below required voltage levels.
Allow sufficient time for batteries to
recharge (36 hours). If batteries have not
recharged after 36 hours, replace the
array accelerator board.
Logical drive X failed
due to cache error
This logical drive failed due to a
catastrophic cache error.
Replace the array accelerator board and
reconfigure using the Array Configuration
Utility.
Logical Drive X
status = FAILED
This status could be issued for several
reasons. If this logical drive is
configured for No Fault Tolerance and
one or more drives fail, this status will
occur. If mirroring is enabled, and any
two mirrored drives fail, this status will
occur. If Data Guarding is enabled, and
two or more drives fail in this unit, this
status will occur. This status may also
occur if another configured logical
drive is in the WRONG DRIVE
REPLACED or LOOSE CABLE
DETECTED state.
Check for drive failures, wrong drive
replaced, or loose cable messages. If there
was a drive failure, replace the failed
drives, then restore the data for this logical
drive from the tape backup. Otherwise,
follow the wrong drive replaced or loose
cable detected procedures.
Logical Drive X
status = INTERIM
RECOVERY
A physical drive in this logical drive
has failed. The logical drive is
operating in interim recovery mode
and is vulnerable.
Replace the failed drive as soon as
possible.
Logical Drive X
status = LOOSE
CABLE DETECTED
A physical drive has a cabling
problem.
Turn the system off and attempt to
reattach the cable onto the drive. If this
does not work, replace the cable.
Logical Drive X
status = NEEDS
RECOVER
A physical drive in this logical drive
has failed and has now been replaced.
This drive needs to be rebuilt from the
mirror drive or the parity data.
When starting the system, select the
F1 - rebuild drive option to rebuild the
replaced drive.