6-36 ES45 Owner's Guide
set dial
The set dial command sets the string to be used by the RMC to dial out when
an alert condition occurs.
The dial string must be in the correct format for the attached modem. If a pag-
ing service is to be contacted, the string must include the appropriate modem
commands to dial the number. The dial string is case sensitive. The RMC
automatically converts all alphabetic characters to uppercase.
RMC> set dial
Dial String: ATXDT9,15085553333
RMC>
For more information, see Section 6.6.5.
set escape
The set escape command sets a new escape sequence for invoking RMC.
The escape sequence can be any character string, not to exceed 14 characters. A
typical sequence consists of two or more control characters. It is recommended
that control characters be used in preference to ASCII characters. Use the
status command to verify the escape sequence.
Be sure to record the new escape sequence. If you forget the escape sequence,
you must reset the RMC to the factory defaults. (See Section 6.7.)
The following example consists of two instances of the Esc key and the letters
“FUN.” The “F” is not displayed when you set the sequence because it is pre-
ceded by the escape character.
RMC> set escape
Escape Sequence: un
RMC> status
.
.
.
Escape Sequence: ^[^[FUN