Compaq AlphaServer ES45 3B Spezifikationen Seite 185

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 322
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 184
Firmware 5-21
5.5.4 Displaying FRUs with Errors
The show error command displays FRUs that have errors logged to the
serial control bus EEPROMs.
Example 5–5 Show Error
P00>>> show error
SMB0 TDD - Type: 1 Test: 1 SubTest: 1 Error: 1
SMB0 SDD - Type: 4 LastLog: 1 Overwrite: 0
P00>>>
The output of the show error command is based on information logged to the
serial control bus EEPROMs. Both the operating system and the ROM-based
diagnostics log errors to the EEPROMs. This functionality allows service pro-
viders to generate an error log from the console environment.
If no errors are logged, nothing is displayed and you are returned to the SRM
console prompt.
Example 5–5 shows errors reported on the system motherboard (SMB0). Con-
tact your service provider if errors are displayed.