2-14 StorageWorks Fibre Channel Storage Switch Sevice Guide
In this error message, one of the following descriptions replaces the term
(regname):
WordsTX – Words transmitted
WordsRx – Words received
FramesTx – Frames transmitted
FramesRx – Frames received
Cl2FrmRx – Class 2 frames received
Cl3FrmRx – Class 3 frames received
LinkCtlFRx – Link control frames received
MCastRx – Multicast received
RDY_XmitPri – Number of times R_RDY has transmit priority higher
than frames
NoTxCredit – No transmit credit available.
NOTE: These register names are the most probable to be displayed in the port register
test error message, however there are other possible register names.
A port register test error message is probably caused by:
Failure of the G_Port and FL_Port ASIC
Failure of the interface module
Interface module connector.