Seitenansicht 250
Event Reporting: Templates and Codes 5–87
8B000186 An single bit error was found by software scrubbing.
Last Failure Parameter [0] contains the address of the first single bit ecc error found.
Last Failure Parameter [1] contains the count of single bit ecc errors found in the same
region below this address.
Last Failure Parameter [2] contains the lower 32-bits of the actual data read at the
Parameter [0] address.
Last Failure Parameter [3] contains the higher 32-bits of the actual data read at the
Parameter [0] address.
Last Failure Parameter [4] contains the lower 32-bits of the expected data at the
Parameter [0] address.
Last Failure Parameter [5] contains the higher 32-bits of the expected data at the
Parameter [0] address.
01
Table 5–18 Last Failure Codes (Sheet 41 of 41)
Code Description
Repair
Action
Code
Seitenansicht 250