QuickSpecs
Compaq TruCluster Server
DA-10514 North America — Version 04 — December 27, 2000 5
H
ARDWARE
R
EQUIREMENTS
(continued)
Supported Memory Channel Hardware
TruCluster Server Version 5.1 requires Memory Channel hardware. Note that there are two variants of Memory Channel (MC):
MC 1 & 1.5 MC2 Description
CCMAA-AA or CCMAA-BA CCMAB-AA PCI Adapter
CCMHA-AA CCMHB-AA Hub
CCMLA-AA CCMLB-AA Line Card
N/A BN39B-04 4-meter Cable
BC12N-10 BN39B-10 3-meter Cable
BN39B-01 (one meter) Connects MC adapter to CCMFB optical
converter
CCMFB-AA Fibre Optics Converter
BN34R-10 Fibre optics cable: Connect one optical
converter to another
BN34R-31 (31 meter) Fiber optics cable: Connect one optical
converter to another
Notes:
• At least one Memory Channel adapter must be installed in a PCI slot in each member system. A link cable(s) is required to connect systems to each
other or to a hub. A cluster environment with two nodes does not require a hub. A configuration of more than two members requires a Memory
Channel hub.
• MC1.5 or MC2 cannot be mixed on the same rail with MC2.
There are special rules about circumstances where Memory Channel 1 and Memory Channel 2 can be used together in the same cluster. The TruCluster
Server Hardware Configuration manual provides information regarding supported Memory Channel configurations.
Supported Fibre Channel Hardware
TruCluster Server supports the following Fibre Channel hardware. For more information on the supported Fibre Channel solutions, please see the
TruCluster Software Products Release Notes and the Hardware Configuration manual.
Device Description
KGPSA-BC PCI-to-Fibre Channel host adapter
KGPSA-CA PCI-to-Fibre Channel host adapter
DS-DSGGA-AA/AB 8/16 port Fibre Channel switch
DS-DSGGB-AA/AB 8/16 port Fibre Channel switch
DS-DSGGC-AA 8 port FC switch
HSG60 Array Controller
HSG80 Array Controller
MA6000 RAID Array
RA8000/MA8000 RAID Array
ESA12000/EMA 12000 RAID Array
Supported SCSI Controllers
The systems are connected to shared SCSI buses using an adapter from the following list. The TruCluster Server Hardware Configuration manual and
Release Notes provide more information regarding SCSI controller configuration, respectively:
• KZPSA - PCI to Fast Wide Differential SCSI-2 adapter
• KZPBA-CB - PCI to UltraSCSI wide differential adapter
Supported SCSI Signal Converters
TruCluster Server Version 5.1 supports the following SCSI signal converters. The TruCluster Server Hardware Configuration manual provides information
regarding supported SCSI signal converters configuration.
Signal Converter Description
DWZZA-AA Standalone unit, single-ended/narrow to differential/narrow
DWZZA-VA SBB, single-ended/narrow to differential/narrow
DWZZB-AA Standalone unit, single-ended/wide to differential/wide
DWZZB-VW SBB, single-ended/wide to differential/wide
DS-DWZZH-03 UltraSCSI hub
DS-DWZZH-05 UltraSCSI hub
Kommentare zu diesen Handbüchern