Table C-1: POST Error Messages
Error Code Audible
Beeps
Probable Source
of Problem
Action
Critical Failure Detected - System
Shutting Down in
None Blower assembly has failed. Replace blower
assembly.
Processor in incorrect socket. -
System Halted!
None Processor is installed in
socket 2 only.
Install processor
in socket 1.
REDUNDANT ROM ERROR:
Backup ROM invalid. - Run
ROMPAQ to correct error condition
None System ROM and
redundant ROM are both
corrupt.
Run ROMPaq
Utility.
REDUNDANT ROM ERROR:
Bootblock invalid. - Contact
COMPAQ Representative
None ROM bootblock is corrupt. Contact
Compaq
authorized
service provider.
805-Unsupported Processor
Detected
System will ONLY boot ROMPAQ
Utility.
None One or both processors are
unsupported.
Install supported
processors.