Managing the System Remotely 10-13
Compaq Confidential – Need to Know Required
Writer: Robert Young Project: AlphaServer DS20E System Comments:
Part Number: ER-K8F6W-UA .A01 File Name: k-ch10 Managing the System Remotely.doc Last Saved On: 10/4/99 1:33 PM
RMC>status
Firmware Rev: V2.0
Escape Sequence: ^]^]RMC
Remote Access: ENABLE
Temp (C): 26.0
RMC Power Control: ON
RMC Halt: Deasserted
External Power: ON
Server Power: ON
RMC>
Table 10-2
RMC Status Command Fields
Item Description
Firmware Rev: Revision of RMC firmware.
Escape Sequence: Current escape sequence to invoke RMC.
Remote Access: Modem remote access state.
(ENABLE/DISABLE)
Temp (C): Current system temperature in degrees
Celsius.
RMC Power Control: Current state of RMC system power control.
(ON/OFF)
RMC Halt: Asserted indicates that halt has been
asserted with the haltin command.
Deasserted indicates that halt has been
deasserted with the haltout command or
by cycling power with the On/Off button on
the control panel. The RMC Halt: field does
not report halts caused by pressing the Halt
button.
External Power: Current state of power to RMC. Always on.
Server Power: Indicates whether power to the system is
on or off.