Compaq DIGITAL Server Cluster Kits for Windows NT Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Vernetzung Compaq DIGITAL Server Cluster Kits for Windows NT herunter. Compaq DIGITAL Server Cluster Kits for Windows NT Installation guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - StorageWorks Secure Path

StorageWorks Secure Pathfor Windows NTA High Availability SolutionInstallation GuideEK–WNTMP–MH. D01 123995–002Compaq Computer Corporation

Seite 3

EK–WNTMP–MH. D01 123995–002 xiAbout This GuideThis section defines the scope, structure and conventions of this guide. It identifies associatedreferen

Seite 4

StorageWorks Secure Path for Windows NTxii 123995–002 EK–WNTMP–MH. D01Chapter 5: Installing Secure Path HardwareThis chapter provides the procedures

Seite 5 - Contents

About This GuideEK–WNTMP–MH. D01 123995–002xiiiConventionsIn this guide, references to RAID, Array, subsystem, HSZ70, RA7000, ESA10000; HSG80,RA8000 o

Seite 7 - Appendix A Quick Setup

EK–WNTMP–MH. D01 123995–002 1–11Theory of OperationThis section provides an overview of StorageWorks Secure Path v2.2 for Windows NT.1.1 An Overview o

Seite 8

StorageWorks Secure Path for Windows NT1-2 123995-002 EK-WNTMP-MH. D011.2 Secure Path TechnologyKey to Secure Path’s functionality is the capability o

Seite 9 - Revision Record

Chapter 1. Theory of OperationEK-WNTMP-MH. D01 123995-002 1-3Secure Path also incorporates the custom Windows NT class driver, HszDisk, developedfor

Seite 10

StorageWorks Secure Path for Windows NT1-4 123995-002 EK-WNTMP-MH. D01Figure 1–1 Secure Path Single Host ConfigurationFigure 1–2 Secure Path Microso

Seite 11 - About This Guide

Chapter 1. Theory of OperationEK-WNTMP-MH. D01 123995-002 1-51.5 The Secure Path Software for Microsoft Windows NTThe Secure Path (v2.2) Software Kit

Seite 12 - Appendix A: Quick Setup

While Compaq Computer Corporation believes the information included in this manual is correctas of the date of publication, it is subject to change wi

Seite 14

EK–WNTMP–MH. D01 123995–002 2–12Choosing an Installation MethodThis chapter describes the two methods, available in this guide, to install and configu

Seite 16 - 1.2 Secure Path Technology

EK–WNTMP–MH. D01 123995–002 3–13Pre-Installation StepsThis section addresses the preparation needed before installing and configuring the Secure Pathc

Seite 17

StorageWorks Secure Path for Windows NT3–2 123995–002 EK–WNTMP–MH. D01Table 3–1 Secure Path Prerequisites (cont)Additional Items RequirementInterconn

Seite 18 - SHR-1274-99EPS

Chapter 3. Pre-Installation StepsEK–WNTMP–MH. D01 123995–002 3–33. For SCSI Raid Array 7000 or ESA 10000 with Windows NT Clusters and SCSI HubsQTY.

Seite 19

StorageWorks Secure Path for Windows NT3–4 123995–002 EK–WNTMP–MH. D013.4 Examine the Current ConfigurationThe next step is to ensure that the existin

Seite 20

Chapter 3. Pre-Installation StepsEK–WNTMP–MH. D01 123995–002 3–53.5.1 Preparing an Existing RAID Array for Secure Path OperationIf you have an exist

Seite 22

EK–WNTMP–MH. D01 123995–002 4–14Installing Secure Path SoftwareThis chapter describes the software configuration procedures required to establish Secu

Seite 23 - Pre-Installation Steps

Achtung!Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb diesesGerätes Rundfunkstörungen auftreten, in welchen

Seite 24

StorageWorks Secure Path for Windows NT4–2 123995–002 EK–WNTMP–MH. D014.2.2 Installing the Secure Path Driver and AgentThe following section describe

Seite 25

Installing Secure Path SoftwareEK–WNTMP–MH. D01 123995–002 4–34.3 Establishing a Serial Link to the RAID SubsystemWhile StorageWorks Command Console (

Seite 26

StorageWorks Secure Path for Windows NT4–4 123995–002 EK–WNTMP–MH. D01HS*** > set nofailoverThe “other” controller will shutdown and must be manual

Seite 27

EK–WNTMP–MH. D01 123995–002 5–15Installing Secure Path HardwareThis chapter provides the procedures for installing and terminating a second individual

Seite 28

StorageWorks Secure Path for Windows NT5–2 123995–002 EK–WNTMP–MH. D015.2.1 Setting Up SCSI Host AdaptersNOTEYou must assure that the connection betw

Seite 29 - 4.1 Summary

Chapter 5. Installing Secure Path HardwareEK–WNTMP–MH. D01 123995–002 5–35.3.1 Installing an RA7000 or ESA10000 (SCSI) and One Windows NT ServerTo es

Seite 30

StorageWorks Secure Path for Windows NT5–4 123995–002 EK–WNTMP–MH. D015.3.2 Installing an RA7000 or ESA10000 (SCSI) and a Windows NT Clusterwith Y-Cab

Seite 31

Chapter 5. Installing Secure Path HardwareEK–WNTMP–MH. D01 123995–002 5–55.3.3 Installing an RA7000 or ESA10000 (SCSI) and a Windows NT Clusterwith S

Seite 32

StorageWorks Secure Path for Windows NT5–6 123995–002 EK–WNTMP–MH. D015.3.4 Installing an RA8000 or ESA12000 (Fibre Channel) and One WindowsNT ServerT

Seite 33 - 5.1 Summary

Chapter 5. Installing Secure Path HardwareEK–WNTMP–MH. D01 123995–002 5–75.3.5 Installing an RA8000 or ESA12000 (Fibre Channel) and a Windows NTClust

Seite 36

EK–WNTMP.MH. D01 123995–002 6–16Using StorageWorks Secure Path ManagerThis chapter describes how to use StorageWorks Secure Path Manager to monitor an

Seite 37

StorageWorks Secure Path for Windows NT6-2 123995-002 EK-WNTMP-MH. D01Figure 6–1 Invoking Secure Path Manager6.2 Secure Path Manager Login and Agent

Seite 38 - NT Server

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-3Each instance of Secure Path Manager is capable of managing one single hostconfig

Seite 39

StorageWorks Secure Path for Windows NT6-4 123995-002 EK-WNTMP-MH. D016.3 Host Connection Status MonitorAs shown in Figure 6-4, Secure Path Manager wi

Seite 40

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-56.4 Path and Drive Status MonitorThe Secure Path Manager screen appears as shown i

Seite 41 - Getting Started

StorageWorks Secure Path for Windows NT6-6 123995-002 EK-WNTMP-MH. D01The port/bus/target/lun information refers to the physical identity of the drive

Seite 42

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-76.6 Balancing the I/O Load Between PathsAs the storage demands of your Secure Path

Seite 43

StorageWorks Secure Path for Windows NT6-8 123995-002 EK-WNTMP-MH. D016.8 Automatic FailoverWhen a path fails, (Secure Path software detects the loss

Seite 44

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-9Figure 6–6 Automatic Disk Failover from Failed Path Controller AColors for Figure

Seite 45

EK–WNTMP–MH. D01 123995–002 vContentsRevision Record About This GuideAudience...

Seite 46

StorageWorks Secure Path for Windows NT6-10 123995-002 EK-WNTMP-MH. D01 6.9 Automatic Failback Auto-failback monitors a failed path and will automatic

Seite 47

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-11 6.10 Manual Failback and Status Reporting Once a failed path is restored, the di

Seite 48 - 6.8 Automatic Failover

StorageWorks Secure Path for Windows NT6-12 123995-002 EK-WNTMP-MH. D016.11 Notification when No-Single-Point-of-Failure is CompromisedWhen a server i

Seite 49 - Controller A

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-136.11.1 No Preferred Path Detectable upon Server Boot If, during server boot oper

Seite 50 - 6.9 Automatic Failback

StorageWorks Secure Path for Windows NT6-14 123995-002 EK-WNTMP-MH. D016.11.2 No Redundant Path Detectable upon Server BootIf, during server boot, Se

Seite 51 - • The NT server is rebooted

Chapter 6. Using Secure Path ManagerEK-WNTMP-MH. D01 123995-002 6-156.12 Adding New Storagesets with Secure PathTo add new storagesets to a Secure Pa

Seite 53

EK–WNTMP–MH. D01 123995–002 A–1AQuick SetupThis section provides simplified installation instructions to enable experienced system integratorsand admi

Seite 54

StorageWorks Secure Path for Windows NTA–2 123995–002 EK–WNTMP–MH. D01Quick Setup GuideforRA7000 or ESA10000 (SCSI) and One Windows NT ServerNOTE Do n

Seite 55

Appendix A. Quick SetupEK–WNTMP–MH. D01 123995–002 A–3STEP 4: Prepare the RAID SubsystemAfter the server has shutdown, perform the following actions

Seite 56

StorageWorks Secure Path for Windows NTvi 123995–002 EK–WNTMP–MH. D014 Installing Secure Path Software4.1 Summary ...

Seite 57 - Quick Setup

StorageWorks Secure Path for Windows NTA–4 123995–002 EK–WNTMP–MH. D01STEP 6: Confirm InstallationAction✔Reboot the serverCheck event log for proper

Seite 58 - Quick Setup Guide

Appendix A. Quick SetupEK–WNTMP–MH. D01 123995–002 A–5Quick Setup GuideforRA7000 or ESA10000 (SCSI) and a Windows NT Cluster withSCSI Y-CablesNOTE Do

Seite 59

StorageWorks Secure Path for Windows NTA–6 123995–002 EK–WNTMP–MH. D01STEP 4: Prepare the RAID SubsystemAfter the server has shutdown, perform the fo

Seite 60 - STEP 6: Confirm Installation

Appendix A. Quick SetupEK–WNTMP–MH. D01 123995–002 A–7STEP 6: Confirm InstallationAction✔Reboot the serversCheck event log for proper SCSI operation

Seite 61

StorageWorks Secure Path for Windows NTA–8 123995–002 EK–WNTMP–MH. D01Quick Setup GuideforRA7000 or ESA10000 (SCSI) and a Windows NT Cluster withSCSI

Seite 62

Appendix A. Quick SetupEK–WNTMP–MH. D01 123995–002 A–9STEP 4: Prepare the RAID SubsystemAfter the server has shutdown, perform the following actions

Seite 63

StorageWorks Secure Path for Windows NTA–10 123995–002 EK–WNTMP–MH. D01STEP 6: Confirm InstallationAction✔Reboot the serversCheck event log for prope

Seite 64

Appendix A. Quick SetupEK–WNTMP–MH. D01 123995–002 A–11Quick Setup GuideforRA8000 or ESA12000 (Fibre Channel) and One Windows NTServerNOTE Do not ins

Seite 65

StorageWorks Secure Path for Windows NTA–12 123995–002 EK–WNTMP–MH. D01STEP 4: Prepare the RAID SubsystemAfter the server has shutdown, perform the f

Seite 66

Appendix A. Quick SetupEK–WNTMP–MH. D01 123995–002 A–13Quick Setup GuideforRA8000 or ESA12000 (Fibre Channel) and a Windows NT ClusterNOTE Do not ins

Seite 67

ContentsEK–WNTMP–MH. D01 123995–002 viiAppendix A Quick SetupRA7000 or ESA10000 (SCSI) and One Windows NT Server...

Seite 68

StorageWorks Secure Path for Windows NTA–14 123995–002 EK–WNTMP–MH. D01STEP 4: Prepare the RAID SubsystemAfter the server has shutdown, perform the f

Seite 69

EK–WNTMP–MH. D01 123995–002 B–1BDe-Installing Secure Path SoftwareThis appendix describes how to remove StorageWorks Secure Path software from your se

Seite 71

EK–WNTMP–MH. D01 123995–002 C–1CTroubleshooting Secure Path Connection ProblemsThis appendix describes general network configuration issues which migh

Seite 72

StorageWorks Secure Path for Windows NTC–2 123995–002 EK–WNTMP–MH. D01 C.2 Network Considerations• Client names up to 15 letters without a dot ("

Seite 74 - C.2 Network Considerations

EK-WNTMP-MH. D01 123995–002 ixRevision RecordThis Revision Record provides a concise publication history of this manual. It lists the manualrevision l

Kommentare zu diesen Handbüchern

Keine Kommentare