HP StorageWorks 1000 Modular Smart Array
maintenance and service guide
This guide provides procedures and diagnostics needed for the maintenance, service, and troubleshooting of the HP
StorageWorks 1000 Modular Smart Array (MSA1000 or MSA).
Part number: 257547–003
Third edition: October 2006
Seitenansicht 0
1 2 3 4 5 6 ... 121 122

Inhaltsverzeichnis

Seite 1 - Third edition: October 2006

HP StorageWorks 1000 Modular Smart Arraymaintenance and service guideThis guide provides procedures and diagnostics needed for the maintenance, servic

Seite 2

User documentation is available in the following locations:• MSA1000/1500 documentation CD• Technical documentation page of the MSA1000 website: http:

Seite 3 - Contents

• RAID 6 configurations can tolerate simultaneous failure of two hard drives in the array.Compromised fault toleranceEach RAID configuration has inheren

Seite 4

b. Make copies of important data, if possible.c. Replace any failed hard drives and allow the Automatic Data Recovery (ADR) process to rebuildthe data

Seite 5

• When RAID 6 (ADG) is used, two drives can fail simultaneously (and be replaced simultaneously)without data loss.•Iftheoffline drive is a spare, the d

Seite 6

Failure of another drive during rebuildIf a non-correctable read error occurs on another physical drive in the array during the rebuild process,the On

Seite 7

104Hard drive failures and faulted LUNs

Seite 8

10 Array controller firmwareEach array controller contains Read-Only Memory (ROM), which holds the firmware that operates thecontroller. In dual-control

Seite 9

If the firmware version on the two controllers is not the same, the following prompt is displayed in thecontroller LCD panel: CLONE FIRMWARE ? ‘<‘ =

Seite 10

The following instructions and examples use HyperTerminal. For more information, see userdocumentation for your emulator program.a. On the menu bar at

Seite 11

6. In dual-controller configurations only, if the newly installed firmware on the recovered controllerdiffers from the firmware on the active controller,

Seite 12 - About this guide

11 SCSI hard drive firmwareSCSI hard drive firmware updates are performed from the bootable ProLiant Firmware Maintenance CDand are required only when t

Seite 13 - 1 Illustrated parts list

HP technical supportFor worldwide technical support information, see the HP support website: http://www.hp.com/support.Before contacting HP, collect t

Seite 14

110SCSI hard drive firmware

Seite 15 - 2Specifications

A Regulatory compliance andsafetyRegulatory complianceFederal Communications Commission noticePart 15 of the Federal Communications Commission (FCC) R

Seite 16 - Chassis specifi

Declaration of conformity for products marked with the FCC logo, United States onlyThis device complies with Part 15 of the FCC Rules. Operation is su

Seite 17 - SCSI I/O mo

European Union noticeProducts bearing the CE marking comply with the EMC Directive (89/336/EEC) and the Low VoltageDirective (73/23/EEC) issued by the

Seite 18 - Specifications

Korean noticesSafety noticesBattery replacement noticeYour computer is equipped with a lithium manganese dioxide, a vanadium pentoxide, or an alkaline

Seite 19 - 3 System components and LEDs

Taiwan battery recycling noticeThe Taiwan EPA requires dry battery manufacturing or importing firms inaccordance with Article 15 of the Waste Disposal

Seite 20 - Chassis and component LEDs

• Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.Wrist straps are flexible straps with a minimum of 1 megoh

Seite 21 - Chassis LEDs

IndexAACcircuit overload, warning,65accumulators, 114ADU, described,30alkaline battery warning, 114audience,9Avis Canadien, regulatory compliance noti

Seite 22 - Controller LEDs

fibre subsystem link failure,56fibre subsystem link OK,56fibre switch hardware failure,56firmware flash done,53firmware fl ashdoneonbox#<n>,53firmware fl

Seite 23 - Hard drive LEDs

device preparationremoving power,70warnings and precautions,65device, unloading from pallet,64diagnostic tools,29disposal, battery,114,115dissipating

Seite 24

12About this guide

Seite 25 - Fibre Channel I/O module LEDs

Federal Communications Commission. SeeFCC,111Fibre Channel I/O modulereplacing,83figuresLEDscontroller,22fibre channel 1/0 module,25firmwarecloning,105cl

Seite 26 - System components and LEDs

storage box fan hot inserted,54storage box fan hot removed,54storage box fan OK,53storage box hot added,55storage box hot removed,55storage box power

Seite 27 - SCSI I/O module LEDs

regulatory complianceinformation number,112noticesBSMI, 113Canada,112Class A, 111Class B,111European Union, 113HP series number,112IEC EMC statement,

Seite 28

1 Illustrated parts list8765243115490ItemDescriptionService replacementmodule part numberAdditional/optionalmodule part numberCustomer Self RepairStan

Seite 29 - 4 Available diagnostic tools

Other available items:SCSI hard drivesContact HP Support Contact your HPAuthorized ResellerOptionalMSA1000 controllerwith 128MB cache314718–001n/aOpti

Seite 30 - Available diagnostic tools

2SpecificationsThis chapter provides operating and performance specifications for the MSA1000.Included in this section:•Chassisspecifications•Memoryspeci

Seite 31

Chassis specificationsItemDescriptionHeight17.5 cm (6.9 in)Width52.1 cm (20.5 in)Depth48.3 cm (19.0 in)Weight (no hard drives installed, single power s

Seite 32

Memory specificationsItemDescriptionSpeed100 MHz minimumWidth 80 bitsNOTE:Use only HP battery-backed cache accelerator modules.Power supply module spec

Seite 34 - LCD message types

3 System components and LEDsThis chapter includes fi gures and tables that identify system components and describe chassis andmodule LEDs patterns.Incl

Seite 35 - LCD message descriptions

Legal and notice information© Copyright 1999, 2002–2006-NaN Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from

Seite 36 - Description Action

Rear view1824 324 3567155781Fibre Channel blanking panel2Power supply/blower assemblies3Power supply/blower assembly LEDs4AC power cord connectors5SCS

Seite 37

Chassis LEDsThe chassis LEDs provide fundamental status information about the MSA.12315582Item NameCondition ColorMeaningBlinkingGreenNormal1Heartbeat

Seite 38

Controller LEDsDuring normal runtime, the array controller has 18 LEDs that indicate controller activity or malfunction.1 0 162345679 8 17101112131415

Seite 39

Hard drive LEDsWhen a hard driveisconfi gured as a part of an array and attached to a powered-on controller, thestatus of the hard drive can be determi

Seite 40

On or Off‘BlinkingOff The hard drive is being accessed in one of the following ways:• Theharddriveisareplacementharddriveandisbeingrebuilt.• If the on

Seite 41

Fibre Channel I/O module LEDsThe Fibre Channel I/O module has three LEDs. The following figure and table describe their locationsand meanings.13215587I

Seite 42

Power supply/fan assembly LEDsEach power supply/fan assembly has one LED.The LED is illuminated when both the power supply and the fan are operational

Seite 43

SCSI I/O module LEDsThe SCSI I/O module with integrated EMU has three LEDs. The following figure and table describetheir locations and meanings.31 2155

Seite 44

28System components and LEDs

Seite 45

4 Available diagnostic toolsThe following is a partial list of the tools that are supported for use with the MSA:•ArrayConfiguration Utility (ACU) over

Seite 46

ContentsAboutthisguide ... 9Intendedaudience... 9Prerequisites ...

Seite 47

• ACU website: http://h18000.www1.hp.com/products/servers/priliantstorage/softwaer-management/acumatrix/index.html.Array Configuration Utility Command

Seite 48

data for reporting and graphing. HP-SIM also provides base-level management of HP clients, printers,and selected storage.HP recommends using HP-SIM to

Seite 49

• Manual and automatic (real-time) analysis capabilities on local or remote machines• Filtering capabilities on error logs• Automatic notification (cus

Seite 50

5 LCD panel and messagedescriptions• LCD panel overview•LCDmessagetypes•LCDmessagedescriptionsNOTE:Some messages may specify a box number. For the MSA

Seite 51

1 2 3 4 567155761Fault LED—indicates an internal MSA component failure or external storage enclosure failure2Two-line, twenty-column text message LCD

Seite 52

User input messagesUser input messages indicate that the system has encountered a situation that allows user input. The usercan select from a number o

Seite 53

Message TypeDescription Action04 ENABLE VOLUMES ?'<'=NO, '>'=YESUser inputAn issue has been foundwith all of the configuredvo

Seite 54

Message TypeDescription Action10 FIRMWARE FLASHFAILEDErrorROM flash failed. Download new firmwarefrom the HP website andinitiate the firmware updateagain

Seite 55

Message TypeDescription Action24 BAD SCSI BUSMODE NON-LVD DEVICEFOUNDErrorThe MSA does notsupport SCSI SingleEnded (SE) devices; itonly supports SCSI

Seite 56

Message TypeDescription Action32 CHASSIS NVRAMCONTENTS CORRUPTEDErrorThe MSA has non-volatilememory on it that containsrequired informationneeded to o

Seite 57

6Customerreplaceablecomponents... 59Proceduraloverview... 60Customerselfrepair ...

Seite 58

Message TypeDescription Action44 REDUNDANCYFAILED MISMATCHHARDWAREErrorBoth array controllers mustcontain the same hardwarefor them to successfullyent

Seite 59 - 6 Customer replaceable

Message TypeDescription Action48 REDUNDANCYHALTED FIRMWARECLONEDInformationalBoth array controllersmust run the same versionof firmware for them tosucc

Seite 60 - Customer self repair

Message TypeDescription Action52 REDUNDANCYFAILED PCI BUSERRORErrorWhile either attemptingto enter redundant modeor already operating inredundant mode

Seite 61 - Recommended tools

Message TypeDescription Action60 NO CACHE MODULEFOUNDErrorThe array controller requiresat least one cache modulein order to operate. Eitherone is not

Seite 62 - Warnings and pr

Message TypeDescription Action67 CACHE HARDWARETEMPORARILYDISABLEDInformationalThe cache memoryhardware has temporarilybeen disabled, typicallybecause

Seite 63 - Equipment symb

Message TypeDescription Action72 CACHE ERROR <n>IGNORE? <=NO, >=YESUser inputDuring power up, data wasfound in the cache thatcould not be

Seite 64 - Rack warnings and precautions

Message TypeDescription Action81 SMART DRIVEALERT BOX #<n>,BAY <n>InformationalA SCSI hard drive may beclose to failing. This wasdetermine

Seite 65

Message TypeDescription Action89 INVALID CONFIGBOX #<n>, BAY <n>ErrorFor the MSA1500, beforeusing an attached MSA20,the MSA20 is checkedto

Seite 66

Message TypeDescription Action106 VOLUME #<n>STATE WAITING TOREBUILDInformational The configured volume iswaiting to start rebuildingdata on a SC

Seite 67 - Determining wh

Message TypeDescription Action112 VOLUME #<n>REBUILD FAILUREErrorThe rebuild operation onthe confi gured volume hasfailed.If the volume is still

Seite 68 - Connecting pow

Replacingafanmodule ... 88Beforeyoubegin ... 88Verifyingcomponentfailure...

Seite 69 - Applying power

Message TypeDescription Action123 TOO MANYVOLUMES DETECTEDErrorThe array controller onlysupports a maximum of32 configured volumes.More volumes than th

Seite 70 - Removing power

Message TypeDescription Action151 BEACON OFFInformationalThe LEDs on the MSA andall connected hard drivesare no longer blinkingbecause the host-baseda

Seite 71 - Removing or ins

Message TypeDescription Action301 RECOVERY ROMAUTOFLASH DONEInformationalThe array controller hassuccessfully completed theprocess of copying thecurre

Seite 72

Message TypeDescription Action306 FIRMWARE FLASHSTARTEDInformationalThe array controller inthe MSA has started thefirmware flash process.Do not turn off

Seite 73 - Replacing a har

Message TypeDescription Action402 STORAGE BOX#<n> FAN DEGRADEDErrorA fan in the specifiedstorage enclosure is notoperating at full efficiency.Thef

Seite 74 - Installing the component

Message TypeDescription Action412 STORAGE BOX#<n> EMU NOTRESPONDINGErrorAn EMU in the specifiedstorage enclosure is notresponding to commands.Mak

Seite 75 - Verifying proper operation

Message TypeDescription Action511 FIBRE CHANNELSUBSYSTEM HARDWAREFAILUREErrorThe array controller's FibreChannel subsystem hasencountered a criti

Seite 76 - Replacing the c

Message TypeDescription Action518 PERSISTENT MEMENABLEDInformationalPersistent memory data hasbeen successfully initialized.519 PERSISTENT MEMDISABLED

Seite 77 - Removing the controller

58LCD panel and message descriptions

Seite 78 - Removing the con

6 Customer replaceablecomponentsThis chapter includes the following information regarding the removal and replacement of MSA1000components:•Procedural

Seite 79

Canadiannotice(avisCanadien) ... 112ClassAequipment... 112ClassBequipment...

Seite 80

Procedural overviewTo help you successfully replace hardware components on your storage system, the following informationis included in all component

Seite 81 - Installing the controller

For more information about HP's customer Self Repair program, contact your local service provider. Forthe North American program, go to: http://w

Seite 82

Warnings and precautions• Electrostatic Discharge Information• Grounding methods•EquipmentSymbols• Weight Warning• Rack warnings and precautions•Devic

Seite 83 - Replacing a Fib

Equipment symbolsThe following symbols may be located on equipment in areas where hazardous conditions may exist.WARNING!Any enclosed surface or area

Seite 84

Weight warningWARNING!The device can be very heavy. To reduce the risk of personal injury or damage to equipment:• Remove all hot-pluggable power supp

Seite 85 - Replacing a 2-Gb

WARNING!Verify that the AC power supply branch circuit that provides power to the rack is not overloaded.Overloading AC power to the rack power supply

Seite 86 - Removing the component

CAUTION:To properly ventilate the system, you must provide at least 7.6 centimeters (3.0 inches) of clearance at thefront and back of the device.CAUTI

Seite 87 - Installin

Determining whether a component is hot-pluggableBefore removing any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable

Seite 88 - Replacing a fan

Connecting power to the MSAHP strongly recommends using the power cord shipped with the MSA. If using a different power cord,your power cordshould be

Seite 89

Applying powerto the MSABefore applying power to the MSA, all components of the storage system must be installed and connectedto the supported interco

Seite 90 - SI I/O module

Tables1..Documentconventions... 102..LCDpanelmessages ... 353..Component hot-pluggability ...

Seite 91 - Installing the c

Removing powerfrom the MSACAUTION:System power to the MSA does not shut off completely with the power switch. The two positions of thefront panel powe

Seite 92

Removing or installing a Fibre Channel interconnect blankBefore you beginCAUTION:• Before removing a component or blanking panel from an operational d

Seite 93 - Replacing the MSA1000 chassis

Removing or installing a hard drive blankBefore you beginCAUTION:• Before removing a component or blanking panel from an operational device, make sure

Seite 94

Replacing a harddriveBefore you beginCAUTION:• Before removing a component or blanking panel from an operational device, make sure that youhave the re

Seite 95 - 7 Enclosure and hard drive

• If you replace a hard drive while the system is off, it may be necessary to rebuild the replacedhard drive.1. Review all warnings, cautions, and pre

Seite 96 - Moving hard drives or arrays

21155933. Close the ejector lever against the front of the hard drive (2).4. Verify that the hard drive is firmly engaged and that the ejector lever is

Seite 97 - 8 Capacity expansion and

Replacing the controller, controller cache, or controller batteryThe following sections detail procedures for replacing an MSA array controller, contr

Seite 98

Verifying component failureBefore replacing the controller, cache module, or battery pack:• Check the controller LCD display panel for error messages.

Seite 99 - Effects of hard drive failure

Removing the controller cache moduleIf your system is equipped with a single controller, and you must replace the controller cache:• You must schedule

Seite 100 - Compromised fa

WARNING!There is a risk of explosion, fire, or personal injury if the battery pack is incorrectly replaced ormistreated. To reduce the risk:• Do not at

Seite 102 - Time required for a rebuild

155175. Lift the pack upward to unhook the top of the battery pack.155186. Wait approximately 15 seconds after removing the old battery to allow the b

Seite 103

5. After the battery pack is hooked in position, swing the pack downward, ensuring that the bottomclip and two pegs line up with the holes in the cach

Seite 104

21155953. If necessary, power on the MSA as instructed in Connecting the Power and Applying power tothe MSA.NOTE:Each time a system with two controlle

Seite 105 - 10 Array controller firmware

Replacing a Fibre Channel I/O moduleBefore you beginCAUTION:• Before removing a component or blanking panel from an operational device, make sure that

Seite 106 - Recovering corrupted firmware

CAUTION:Use appropriate precautions when handling Fibre Channel cables:• Touching the end of a Fibre Channel cable will either damage the cable or cau

Seite 107

Replacing a 2-Gbsmall form factor pluggable (SFP) transceiverThe transceiver is hot-pluggable, so it is not necessary to power down the system to repl

Seite 108 - Array controller firmware

Verifying properoperationAfter replacingthe failed SFP, verify that:• The 1-Gb and 2-Gb link-status LEDs on the Fibre Channel I/O module cycle through

Seite 109 - 11 SCSI hard drive firmware

3. While lifting up the power supply module latch (1), grasp the fan element and pull the defectivepower supply assembly out of the chassis (2).121555

Seite 110 - SCSI hard drive firmware

Replacing a fanmoduleThe variable-speed fan module is hot-pluggable, so it is not necessary to power down the system toreplace it.Before you beginCAUT

Seite 111 - A Regulatory compliance and

11215555CAUTION:Pressing the center section of the fan can damage the blades. Press only the outer edgeof the fan.Installing the component1. Align the

Seite 112 - Canadian

About this guideThis guide provides information about:• Maintaining the MSA• Servicing the MSAWARNING!To reduce the risk of personal injury from elect

Seite 113 - Japanese notice

Replacing the SCSI I/O moduleCAUTION:The SCSI I/O module with an integrated EMU is not hot-pluggable. Before replacing the module, all I/Ofrom the ser

Seite 114 - Safety notices

Installing the component1. Slide the replacement SCSI I/O module into the bay until it clicks into place.155602. Reconnect all SCSI cables.NOTE:Ensure

Seite 115 - Electrostatic discharge

Verifying component failureBefore replacing the power button module:• Verify that themodule status LED is not illuminated or is flashing amber.• Check

Seite 116

Installing the component1. Slide the replacement power button module into the bay until it clicks into place.2. Reinstall allhard drives in slots 10–1

Seite 117

94Customer replaceable components

Seite 118

7 Enclosure and hard drivemigrationsThis section describes the following:• Adding a new storage enclosure• Migrating existing enclosures• Moving hard

Seite 119

4. Attach SCSI cables to the MSA expansion SCSI connectors.5. Attach the SCSI cables to the expansion storage enclosures.6. Attach the power cords to

Seite 120

8 Capacity expansion andextensionArray expansion is the addition of physical hard drives to an array that has already been confi gured. Thecapacity of

Seite 121

98Capacity expansion and extension

Seite 122

9 Hard drive failures and faultedLUNsThe purpose of fault-tolerant array configurations is to protect against data loss due to hard drive failure.Each